• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
Saajos Group

Saajos Group

Enemmän kuin 70 vuotta tulenkestävää laatua.

  • Home
  • Products
    • Marine fire doors
    • Construction fire doors
    • Industrial specialities
  • About us
  • References
  • Contacts
  • English
  • Finnish

Construction fire doors

Stone Foundation of the Fire Safety
Saajos is one of the most remarkable fire and safety door producers in the field of construction industry around the Baltic Sea. Typical targets are hotels, shopping centres, hospitals, industrial plants and public buildings. Our goal is to offer only top quality engineering and products.

HINGED FIRE DOORS

Most common type of fire door. Used in passageways of buildings between the fire compartments. Saajos Fire Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600

Size limitation in fire classified doors

FIRE RATINGMINIMUMMAXIMUM
EI2120 (double door)13,1 x 17,28Mwidth 29,87M and height 26,44M, however, surface area max. 7,1 m2
EI2120 (single leaf)6,1 x 17,28Mwidth 12M and height 23M
EI260 (double door)10,1 x 16,52Mwidth 22,97M and height 25,28M, however, surface area max. 5,2 m2
EI260 (double door)5,1 x 15,77Mwidth 11,47M and height 24,13M, however, surface area max. 2,45 m2
EI230 (double door)12,6 x 18Mwidth 28,6M and height 27,5M, however, surface area max. 7,1 m2
EI230 (single leaf)6,5 x 18Mwidth 13M and height 24M

Equipment

  • door leafs are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of steel
  • Abloy One Fit lock fitting
  • reinforcements for pull and closer
  • cover caps for fastening holes
  • quick latch installed (double doors only)
  • instructions for installation, handling, maintenance and painting

Accessories

  • kick plates
  • alternative quick latch (double doors)
  • different door closer types
  • window, max 460 x 560 mm
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • fitting for security lock
  • type approved frame with gasket, U-value < 1,0 W/m2K
  • alternative surface handling and powder painting, standard shades

Other accessories and iron mongery according to tender.

SLIDING FIRE DOORS

Sliding fire door is needed when the construction opening is large. The door is installed on the wall on top of the opening where it moves along the wall on a rail. Features below are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1

Maximum size for fire classified door leaf (width x height): 6000 mm x 5162 mm.

E 120 -class door doesn’t require safety distance.

Equipment

  • door leaf is made of zinc-coated steel plates
  • electro-galvanized slide rail with fasteners
  • electro-galvanized rollers with bearings
  • fire emergency closing equipment:
  • PSL manual emergency closer for max. 600 kg normally open doors
  • E6LDC fire emergency closer for automatically functioning doors
  • E6LDC fire emergency closer with force controlled buttons
  • smoke and/or heat detector
  • cup or bar puller
  • lower guide and door stopper
  • protective painting on non-galvanized steel parts
  • installation and maintenance instrutions

Accessories

  • cut-outs for monitoring equipment
  • kick plates
  • crush barrier
  • painting

FIRE HATCHES

Fire hatches are tested and classified according to the requirements for hinged fire doors. Features are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600

Fire rating EI230:

  • square-shaped (outer dimension of frame) minimum size is 475 x 475 mm, max 1093 x 1093 mm
  • rectangular-shaped (outer dimension of frame) minimum size is 297 x 372 mm, max 683 x 855 mm, surface area max. 0,53 m2

Equipment

  • hatches are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of steel
  • Abloy One Fit lock fitting
  • reinforcements for pull and closer
  • cover caps for fastening holes
  • instructions for installation, handling, maintenance and painting
  • threshold same profile as the other parts of the frame

Accessories

  • kick plates
  • different door closer types
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • alternative surface handling and powder painting, standard shades

PRESSURE-PROOF FIRE DOORS

Pressure-proof fire doors have been designed and tested to withstand the stress of a pressure impact in addition to “standard fire door”. Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600
  • Pressure impact has been tested at Laboratory of air handling technology at VTT Expert Services, Finland
  • Flying particles and hurricane test have been performed for HPO door according to standards ASTM E 1886-05 and ASTM 1996-09

HFO = EI260, HPO = EI245

Minimum size classified HFO: 5,1 x 15,88M
Maximum size classified HFO (double door): width 22,97M and height 25,28M, however, surface area max 5,2 m2
Maksimikoko luokiteltuna HPO: width 1371 mm and height 2546 mm, however, surface area max. 3,167 m2

Equipment

  • door leafs are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of steel
  • 3-point lock
  • reinforcements for pull and closer
  • cover caps for fastening holes
  • quick latch installed (double doors only)
  • instructions for installation, handling, maintenance and painting

Accessories

  • kick plates
  • alternative quick latch (double doors)
  • different door closer types
  • fitting for security lock
  • alternative surface handling and powder painting, standard shades

Other accessories and iron mongery according to tender.

BURGLARY RESISTANT FIRE DOORS

Locations that require burglar resistance in addition to fire safety. Burglary resistance features are expressed according to the classification standard SFS-EN 1627 and fire-proof features according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600
  • Burglary resistance is tested acc. to SFS-EN 1628, 1629 and 1630, class 3

Minimum size as classified fire door: 5,1 x 15,77M
Maximum size as classified fire door (double door): width 22,97M and height 25,28M, however, surface area max. 5,2 m2

Equipment

  • door leaves are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of hardened steel
  • lock cases acc. to SFS-ENV 1627
  • reinforcements for pull and closer
  • safety pins
  • instructions for installation, handling, maintenance and painting
  • cover caps for fastening holes
  • quick latch installed (double doors only)

Accessories

  • kick plates
  • different door closer types
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • alternative quick latch (double doors)
  • alternative surface handling and powder painting, standard shades

Other accessories and iron mongery according to tender.

ACOUSTIC FIRE DOORS

Locations that require airbourne sound insulation in addition to fire safety. Acoustic features are expressed according to the classification standard ISO 717-1 and fire-proof features according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600
  • Airbourne sound insulation is tested acc. to ISO 140-3, RW = 34 dB

Minimum size as classified fire door: 5,1 x 15,77M
Maximum size as classified fire door: width 11,47M and height 24,13M

Equipment

  • door leafs are made of zinc-coated steel plates
  • screw-fastening frame with cover lists, made of zinc-coated steel plates
  • lift hinges of steel
  • Abloy One-fit lock fitting
  • reinforcements for pull and closer
  • cover caps for fastening holes
  • instructions for installation, handling, maintenance and painting

Accessories

  • kick plates
  • different door closer types
  • window, max 460 x 560 mm
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • fitting for security lock
  • alternative surface handling and powder painting, standard shades

Other accessories and iron mongery according to tender.

GLAZED FIRE DOORS

Profile construction fire door. Used in passageways of buildings between the fire compartments. Glazed Fire Doors are made of non-combustible materials that prevent fire spreading for certain time. Features are indicated according to the classification standard SFS-EN 13501-2:

  • Capability to prevent fire and flame spread are tested acc. to fire test standard SFS-EN 1634-1
  • Mechanical strength is tested acc. to SFS-EN 14600

Size limitation in fire classified doors according to the type approvals.

Equipment

  • frame and door parts are made of steel profiles
  • glazed with glasses in accordance to the type approval
  • welded steel lift-hinges with bearings
  • Fitting for Abloy profile lock
  • reinforcements for pull and closer
  • quick latch installed (double doors only)
  • instructions for installation, handling, maintenance and painting

Accessories

  • kick plates
  • alternative quick latch (double doors)
  • different door closer types
  • fitting and tubing for electric lock, door magnet, wires and lead cover, locations and models acc. to type approvals
  • fitting for security lock
  • alternative surface handling and powder painting, standard shades

Other accessories and iron mongery according to tender.

BULLET-PROOF DOORS

Test standard DIN 52 290.

ModuleOpening in wallOuter dimension of frame
D x F
B x HClear opening
Y x Z
9 x 21 M900 x 2100960 x 2130840 x 2065800 x 2045
10 x 21 M1000 x 21001060 x 2130940 x 2065900 x 2045

WEIGHT (DOOR + FRAME) AND TYPE CODE

Module310.1309.3308.1K308/415A
9 x 21 M130 kg140 kg200 kg215 kg
10 x 21 M140 kg150 kg220 kg235 kg

Equipment

  • door leaves made of zinc-coated steel plate, not painted
  • screw-fastening frame with cover lists, made of electro-galvanised steel
  • hardened lift-up steel hinges with grease nipples
  • Abloy One-fit lock fitting
  • reinforcements for door closer and puller
  • mounting and painting instructions

Accessories

  • kick plates
  • different types of door closers
  • different types of latches for double doors
  • fitting for security lock
  • different types of handles, pullers etc. mounted
  • fitting for electric lock, monitoring equipment and lead cover
  • different types of surface finishing

Other accessories and iron mongery according to tender.

CONSTRUCTION DIVISION DOWNLOADS

Installation, maintenance instructions (in Finnish) (pdf)

Selected drawings and documents for construction industry products (pdf)

  • SA-27163B EI2120 hinged fire doors
  • SA-25877 EI260 hinged fire doors
  • SA-26272G EI230 hinged fire doors
  • SA-25992 sliding fire doors
  • JANSEN profile system for glazed products
  • FORSTER steel profile system for doors and windows
CERTIFICATES AND APPROVALS FOR CONSTRUCTION INDUSTRY

CE-marked sliding doors and external doors

  • EI160 sliding fire door: DoP (in Finnish), certificate 1336-CPR-0192
  • EI260 hinged external doors, single and double: DoP (in Finnish), certificate 1336-CPR-0193
  • Glazed external fire doors made of EI60 Jansen Janisol profiles: DoP (in Finnish), certificate 1336-CPR-0201
  • Glazed external fire doors made of EI30 Jansen Janisol profiles: DoP (in Finnish), certificate 1336-CPR-0200
  • Hinged door, single and double: DoP (in Finnish)
  • Sliding door: DoP (in Finnish)
  • Glazed door made of Forster Unico profiles: DoP (in Finnish)

Hinged solid doors and hatches (in Finnish unless otherwise stated)

  • EI230 hatch EUFI29-22001514-THTOD EI30-luukku
  • Single leaf hinged fire door EI230 EUFI29-19006251-THTOD
  • Double door EI230 EUFI29-21002136-THTOD
  • Single leaf fire door EI260 EUFI29-20005918-THTOD
  • Double door EI260 EUFI29-20005917-THTOD
  • Ståldörrar UFD 125 och UFD126 EI260 (Swedish) RISE SC0569-11
  • Single leaf EI2120 EUFI29-19001612-THTOD
  • Double door EI2120 EUFI29-20004202-THTOD
  • Certificate of Type Approval Nro 14601-01 Steel structure EI30 hatches, single leaf doors and double doors
  • Certificate of Type Approval Nro 14600-01 Steel structure EI60 single leaf doors and double doors
  • Certificate of Type Approval Nro 14599-01 Steel structure EI120 single leaf doors and double doors
  • Verification of RC3-class burglary test EUFI29-24004651-T2 single leaf and double leaf doors

Glazed profile fire doors (in Finnish)

  • EI230 Glazed single and double leaf fire door (in Finnish): EUFI29-20004587-THTOD
  • E30 Glazed single and double leaf fire door (in Finnish): EUFI29-20002603-THTOD Forster Presto E30
  • Doors made of Janisol 2 EI 30 -system steel profiles (in Finnish): EUFI29-20004875-THTOD
  • Doors made of Janisol C4 EI260 -system steel profiles (in Finnish): EUFI29-20005916-THTOD
  • Doors made of Forster Fuego Light 60 -system steel profiles (in Finnish): EUFI29-21005961-THTOD

Primary Sidebar

Products

  • Marine fire doors
  • Construction fire doors
    • References
  • Industrial specialities

Footer

Home
Products
Group
References
Contacts




Saajos Oy
Puistokatu 21
FI-08150 Lohja
FINLAND

Contact information

·Toteutus ja ylläpito MMD Networks·

Manage cookie consent
This website uses cookies. These cookies are necessary for a website to function properly. We use cookies also to analyse our traffic. If you don't want to accept the analytics cookies, please click "Dismiss". For more information
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
Preferences
{title} {title} {title}